home *** CD-ROM | disk | FTP | other *** search
/ GameWare Collection / GameWare Collection (CMS Software) (1993).iso / games / n_games / nuke.exe / OAKFLAT.HLP < prev    next >
Text File  |  1991-08-04  |  21KB  |  389 lines

  1.  
  2.                  --<<< SIMULATOR COMMAND SUMMARY LIST >>>--
  3.  
  4.         A                        INSPECTION              SOUND OFF
  5.         ACCIDENT                 MANUAL                  SRCP ON
  6.         ALARM TEST               PRCP ON                 SRCP OFF
  7.         AUTO                     PRCP OFF                SPEED n
  8.         AUTO SHUTDOWN            PPRV OPEN               SPRV OPEN
  9.         COLOR                    PPRV CLOSED             SPRV CLOSED
  10.         DAMAGE                   PRETEST                 TARGET
  11.         DAMAGE CONTROL ON        QUIT                    TOWER PUMP ON
  12.         DAMAGE CONTROL OFF       REFUEL                  TOWER PUMP OFF
  13.         DELAY n                  REPAIRS                 TURBINE TRIP
  14.         DEMAND ON                RESTART                 V
  15.         DEMAND OFF               RESTORE                 VALUE
  16.         DEMO                     RUN UNTIL n             VALVE 1 OPEN
  17.         DOCS                     SAVE                    VALVE 1 CLOSED
  18.         DOCUMENTATION            SCRAM                   VALVE 2 OPEN
  19.         EXIT                     SHIELD ON               VALVE 2 CLOSED
  20.         I                        SHIELD OFF              VIEW ON
  21.                                  SOUND ON                VIEW OFF
  22.  
  23.            All of these commands may be entered by pressing <F7> 
  24.                   and typing the command at the prompt.
  25.  
  26.  
  27.  
  28.                --<<< SIMULATOR COMMAND QUICK HELP LIST >>>--
  29.  
  30.    A = AUTO START Command.
  31.    ACCIDENT = Simulates a sudden loss-of-coolant accident.
  32.    ALARM TEST = Tests all of the audible alarms if SOUND is active. 
  33.    AUTO = Activates Automatic Control Mode.
  34.    AUTO OFF = Initiates an Automatic Shutdown and then ends the simulation.
  35.    AUTO SHUTDOWN = Initiates an Automatic Shutdown then repairs/refueling.
  36.    COLOR = Optimizes the simulators display for a color monitor.
  37.    DAMAGE = Sets the quality of PCS and SCS to POOR (results in damage).
  38.    DAMAGE CONTROL ON = Activates automatic Damage Control Computer.
  39.    DAMAGE CONTROL OFF = De-activates automatic Damage Control Computer.
  40.    DELAY n = Activates a n second pause after each simulated hour (n = 1 - 60).
  41.    DEMAND ON = Activates Varying Demanded Power levels option.
  42.    DEMAND OFF = De-activates Varying Demanded Power Level option.
  43.    DEMO = Activates the interactive Demo Mode.
  44.    DOCS = View DOCUMENTATION using HYPERhelp.
  45.    DOCUMENTATION = View DOCUMENTATION using HYPERhelp.
  46.    EXIT = Quit the simulation immediately to DOS.
  47.    I = INSPECTION command.
  48.    INSPECTION = Reports the last NRC inspection of PCS and SCS.
  49.    MANUAL = De-activates Automatic adjustment of temp/power control settings.
  50.    MONO = Optimizes the simulators display for a monochrome monitor.
  51.    PRCP ON = Turns on the Primary Reserve Coolant Pump.
  52.    PRCP OFF = Turns off the Primary Reserve Coolant Pump.
  53.    PPRV OPEN = Opens the Primary Pressure Release Valve.
  54.    PPRV CLOSED = Closes the Primary Pressure Release Valve.
  55.    PRETEST = Tests all simulated reactor components prior to starting.
  56.    QUIT = Quits the simulation displaying your final score.
  57.    REFUEL = Replaces the reactors fuel rods to 100%.
  58.    REPAIR = Does a complete repair job on all systems having any damage.
  59.    RESTART = Restarts the simulator and resets all settings.
  60.    RUN UNTIL n = Run the simulator until the n day is reached (n = 1 - 2000).
  61.    SCRAM = Immediately takes the reactor off-line in an emergency.
  62.    SHIELD ON = Activates an anti-neutron radiation shield, lowers radiation.
  63.    SHIELD OFF = Turns off the SHIELD option.
  64.    SPEED n = Sets the calculate to view ratio for simulated hours (n = 1 - 24).
  65.    SOUND ON = Activates the SOUND option.
  66.    SOUND OFF = De-activates the SOUND option.
  67.    SPRV OPEN = Opens the Secondary Pressure Release Valve.
  68.    SPRV CLOSED = Closes the SPRV if the valve is open.
  69.    SRCP ON = turns on the Secondary Reserve Coolant Pump.
  70.    SRCP OFF = Turns off the Secondary Reserve Coolant Pump.
  71.    TARGET = Allows for manual setting of Demanded Power level.
  72.    TOWER PUMP ON = Turns on the Cooling Tower Pumps.
  73.    TOWER PUMP OFF = Turns off the Cooling Tower Pumps.
  74.    TURBINE TRIP = By-passes the Steam Turbines in emergency.
  75.    V = Value command.
  76.    VALUE = Displays the current value of the power generated by the plant.
  77.    VALVE 1 OPEN = By-passes Steam Turbine Group #1 in emergency.
  78.    VALVE 1 CLOSED = Closes the by-pass valves for Turbine Group #1.
  79.    VALVE 2 OPEN = By-passes Steam Turbine Group #2 in emergency.
  80.    VALVE 2 CLOSED = Closes the by-pass valves for Turbine Group #12
  81.    VIEW ON = Activates automatically changing view screens.
  82.    VIEW OFF = De-activates automatically changing view screens.
  83.  
  84.  
  85.  
  86.                  --<<< SIMULATOR COMMAND DETAIL LIST >>>--
  87.  
  88.    (A description of the available commands at the <F7> Command Prompt)
  89.  
  90.   A = AUTO START Command.
  91.  
  92.   ACCIDENT = Simulates a sudden loss of coolant accident where there is a
  93.           profound loss of coolant.  For the purpose of the simulator,
  94.           a rapid loss of coolant accident could empty the primary coolant loop
  95.           of all coolant in less than 20 hours.  Counter measures to replace
  96.           the coolant and stop the leak could slow, or even stop a meltdown.
  97.           Once this command is entered it can not be aborted.  If the option
  98.           creates a reactor core meltdown the simulation run is ended.  Only
  99.           use this option to see how devastating such an accident could be,
  100.           and to practice emergency procedures for such an event.
  101.  
  102.    ALARM TEST = Sounds the hourly temperature change alarm, the attention 
  103.           alarm, the warning alarm, and the emergency alarm to test the audio 
  104.           system in the computer.  If the sound is turned OFF no alarms will
  105.           be heard during the test.  Use the SOUND command to turn the 
  106.           speaker back ON.
  107.  
  108.    AUTO = Automatically adjusts the simulators control settings to maintain 
  109.           the power output at or near 100%. MANUAL reverses the command.  
  110.           Controlled by the Auto Adjustment computer, AUTO will adjust CONTROL
  111.           RODS, PCP, SCP, and ECP to maintain a consistent output, and will 
  112.           automatically repair major plant damage (Damage > 25%) and refuel 
  113.           the reactor when needed (Using the AUTO SHUTDOWN command).  It will 
  114.           not maintain coolant levels with the PRIMARY and SECONDARY RESERVE 
  115.           COOLANT PUMP.
  116.  
  117.    AUTO OFF = Initiates the Automatic ShutDown Procedures which will
  118.           set the CONTROL RODS = 0 and turn off the RESERVE COOLANT PUMPS
  119.           if they are activated.  This procedure is activated automatically
  120.           while in the AUTO mode and the FUEL REMAINING < 11 or the TOTAL
  121.           DAMAGE > 24%.  Once the reactor is shutdown the simulation will
  122.           automatically end and your performance will be evaluated.
  123.  
  124.    AUTO SHUTDOWN = Initiates the Automatic ShutDown Procedures which will
  125.           set the CONTROL RODS = 0 and turn off the RESERVE COOLANT PUMPS
  126.           if they are activated.  This procedure is activated automatically
  127.           while in the AUTO mode and the FUEL REMAINING < 11 or the TOTAL
  128.           DAMAGE > 24%.  When the reactor is shutdown, repairs and/or refueling
  129.           procedures will be initiated if the simulator is in AUTO or DEMO mode.
  130.  
  131.    AUTO START = Starts the simulator in AUTO mode, but in addition to the
  132.            normal settings, the DOUBLE option, the DAMAGE CONTROL option,
  133.            and the DEMAND option are all activated.
  134.  
  135.    DAMAGE = Sets the Quality of the workmanship of both the Primary and 
  136.           Secondary Coolant Systems to POOR.  The effect of this is to create 
  137.           substantial amounts of damage to the plant.
  138.  
  139.    DAMAGE CONTROL ON = Instructs the computer to initiate Damage Control 
  140.           automatically on any significant damage found in the plant.  The
  141.           equivalent manual command would be the <F8> function.  The automatic
  142.           system activates emergency repairs when an individual systems 
  143.           damage exceeds 6%.  If the fuel level is less than 12% then repairs
  144.           are started at damage equal to, or greater than 5%.  Coolant Levels
  145.           are also monitored and Reserve Coolant is pumped into the loops as
  146.           needed via the RCP.
  147.  
  148.    DAMAGE CONTROL OFF = Turns off automatic Damage Control.
  149.  
  150.    DELAY n = Activates a n second pause after each simulated hour that passes.
  151.           Should be used when the user wants to slow the amount of time
  152.           between simulated hours.  Many new users will find this option
  153.           very helpful as they are learning the simulation.  To turn of the
  154.           delay use the DELAY 0 command.
  155.  
  156.    DEMAND ON = The Demanded Power Level is displayed on the Main Control Panel
  157.           display as " % DMD ", and indicates how much power should be 
  158.           generated at that time.  The usual Demand is 100%, but this will be 
  159.           randomly changed when Demand is set ON.  The TARGET command allows
  160.           users to manually set the DEMAND level from the command prompt.
  161.          
  162.    DEMAND OFF = Turns off changing Demanded Power Level option.
  163.  
  164.    DEMO = This command is used do demonstrate the operation of the simulator.
  165.           It will PRETEST and power up the plant with the following settings:
  166.            AUTO ON    FAST    SHORT    BLANK ON    DAMAGE CONTROL ACTIVATED
  167.                         DEMAND ACTIVATED    RUN UNTIL 100
  168.           These settings will remain in effect through-out the simulation 
  169.           unless they are de-activated.  To de-activate the DEMO mode use
  170.           the MANUAL or AUTO command.  The DEMO command will initiate the
  171.           PRETEST command if DEMO is entered when the core is at 65°F.  
  172.           Entering the command at any other time will activate the DEMO mode
  173.           but will not PRETEST any systems.
  174.  
  175.    DOCS = DOCUMENTATION Command.
  176.  
  177.    DOCUMENTATION = Displays the simulators help file (OAKFLAT.DOC) using
  178.           HYPERhelp.  The cursor keys, <PgUp>, <PgDn>, <Home>, and <End>
  179.           will view different parts of the file, while <ESC> quits
  180.           HYPERhelp and returns back to the simulator.
  181.  
  182.    EXIT = Quit the simulation without displaying your final score, or
  183.           the option or restarting the simulation or quit to DOS.  Once
  184.           the EXIT command is entered at the command prompt, the screen
  185.           is cleared and the simulation has aborted back to DOS.  All 
  186.           information about the simulation is lost.  This command should
  187.           only be used to quickly exit the simulation when the operator
  188.           DOES NOT want his or her evaluation.  To receive an evaluation
  189.           the QUIT command must be used.
  190.  
  191.    I = INSPECTION command.
  192.  
  193.    INSPECTION = Reports the last NRC inspection info on the Primary System 
  194.           (reactor, PCS, & part of the Heat Exchanger, and the Secondary 
  195.           System (part of Heat Exchanger, SCS, Condenser, & Cooling Towers).
  196.  
  197.    MANUAL = Turns off automatic output control, so the simulator will depend
  198.           on the users input of CONTROL ROD, PCP, and SCP settings to maintain
  199.           constant power output.  To de-activate the manual control command, 
  200.           enter the AUTO of DEMO command at the prompt.  
  201.  
  202.    PRCP ON = Activates the Primary Reserve Coolant Pump, moving reserve
  203.           coolant from the PCS to the SCS.  This increases the amount of
  204.           primary coolant while reducing the reserve coolant level.  To
  205.           de-activate the option, use the PRCP OFF command.
  206.  
  207.    PRCP OFF = Turns off the Primary Reserve Coolant Pump.
  208.  
  209.    PPRV OPEN = Opens the Primary Pressure Release Valve and lowers the
  210.           pressure in the primary loop.  As the pressure drops, so will the
  211.           reactor and heat exchangers temperatures.  Since the steam is really
  212.           just super heated primary coolant, the coolant level in the PCS
  213.           drops each hour.  NOTE: Once the valve is open it must be closed or
  214.           all of the primary coolant could be lost if the valve is left open
  215.           for too long.  Watch the coolant levels while using this option.
  216.  
  217.    PPRV CLOSED = Closes the PPRV if the valve is open and has no effect if 
  218.           the valve is already closed.
  219.  
  220.    PRETEST = Tests all simulated reactor components prior to starting
  221.           the reactor from a complete power down, including a test of
  222.           Alarm System (if the SOUND is ON).  The reactor core is also
  223.           preheated before power up.  This reduces the chances of coolant 
  224.           system damage and adds 1000 points to the score.
  225.  
  226.    QUIT = Quits the simulation displaying your final score, and restart the 
  227.           simulation or quit to DOS.
  228.  
  229.    REFUEL = Replaces the reactors fuel rods after the core temperature
  230.           drops to  62° F.  Any repairs needed are done automatically
  231.           before the refueling is started.  Once the refueling is complete,
  232.           the main display appears with the simulator indicating the change
  233.           in fuel level, days simulated, damage, and expenses.
  234.  
  235.    REPAIR = Does a complete repair job on all systems having any damage.
  236.           The amount of time needed and the costs of repairs are based
  237.           on the amount of damage present at the time of repairs.  The
  238.           days needed to complete the repairs are added to the days simulated
  239.           variable, and the expenses of the repairs are added to the expenses.
  240.  
  241.    RESTART = Restarts the simulator from the title screen, all current
  242.           simulator settings and values are lost.  It has the same effect
  243.           as exiting the simulation and re-running the simulator from the
  244.           DOS prompt.
  245.  
  246.    RUN UNTIL = Allows the user to set the number of days the simulator will run
  247.           before evaluation.  The default number of days is 1000, but it can
  248.           be set between 1 and 2000.
  249.  
  250.    SCRAM = All Control Rods are immediately inserted back into the
  251.           reactor core to cause the spontaneous shut down of the thermal
  252.           nuclear reaction.  The simulator will properly shut down the
  253.           reactor to begin cooling down for repairs.  Use this command
  254.           only for extreme emergencies since it is very expensive!
  255.  
  256.    SHIELD ON = Activates an advanced electronic radiation shield that will
  257.           reduce (not eliminate) radiation exposure.  The shield will reduce
  258.           the number of neutrons that escape the standard protective shielding
  259.           by 60%.  The cost of this added protection is the loss of all 
  260.           supplemental views (<F9> screens), and a lower hourly score.  To 
  261.           de-activate the option use the SHIELD OFF command.  The SHIELD 
  262.           option can be activated and de-activated as needed.
  263.  
  264.    SHIELD OFF = Turns off the SHIELD option.
  265.  
  266.    SOUND ON = Toggles the Speaker Sound Status on and off.  If the Status Line
  267.           displays " SND " the SOUND option is activated.    
  268.  
  269.    SOUND OFF = Turns off the SOUND option.  Once the command is entered, the
  270.           Status Line will change displaying a "NoSND" indicating the SOUND 
  271.           option is off.
  272.  
  273.    SPEED n = The optional setting for length, which displays n hours worth of 
  274.           plant operations with each display pass.  The startup default value
  275.           is n = 1, display 1 hours worth of operation with each display pass.
  276.           To return the speed to the default value, enter SPEED 1 at the 
  277.           command prompt.
  278.  
  279.    SPRV OPEN = Opens the Secondary Pressure Release Valve and lowers the 
  280.           pressure in the primary loop.  As the pressure drops, so will the
  281.           condenser temperature and turbine output.  Since the steam is super
  282.           heated secondary coolant, the coolant level drops in the SCS.
  283.           NOTE: Once the valve is opened using this command, it must be shut
  284.           or all the secondary coolant could be lost.  Use the SPRV CLOSED
  285.           command to shut the valve and carefully watch the coolant levels 
  286.           while using this command.
  287.  
  288.    SPRV CLOSED = Closes the SPRV if the valve is open and has no effect if 
  289.           the valve is closed.
  290.  
  291.    SRCP ON = Activates the Secondary Reserve Coolant Pump, moving reserve
  292.           coolant from the RCS to the SCS.  This increases the amount of
  293.           secondary coolant while reducing the reserve coolant level.  To
  294.           de-activate the option, use the SRCP OFF command.
  295.  
  296.    SRCP OFF = Turns off the Secondary Reserve Coolant Pump.
  297.  
  298.    TARGET = Sets the Demanded Power Level to a percentage between 10% and
  299.           100%.  This command is useful when the AUTO or DEMO options are
  300.           activated.  The computer will automatically adjust the control
  301.           settings to maintain the power output at the demanded percentage.
  302.           To use the command , enter "TARGET " followed be the requested
  303.           target demand level.  To set the level at 80% enter "TARGET 80"
  304.           at the <F7> command prompt.  To reset the demand level to 100% 
  305.           enter "TARGET 100", and to display the status of the option type
  306.           "TARGET" alone at the command prompt.
  307.  
  308.    TOWER PUMP ON = Activates the pumps responsible for pumping coolant from 
  309.            the CONDENSER to the COOLING TOWERS and back again.  The coolant
  310.            flows through the coils inside the CONDENSER to cool the secondary
  311.            coolant as it comes from the TURBINES on its way back into the
  312.            STEAM GENERATOR.  If the TOWER PUMPS are not activated the 
  313.            CONDENSER will overheat and damage will occur.  When in AUTO mode
  314.            the pumps will automatically activate when the CONDENSER COILS
  315.            reach 96°F.  The pumps will also de-activate at 96° while in any
  316.            mode.
  317.                       
  318.    TOWER PUMP OFF = De-activates the TOWER PUMPS from the command prompt.
  319.  
  320.    TURBINE TRIP = Automatically opens Steam Valves #1 and #2, thus by-passing
  321.           the Turbines and thus the generation of electrical power.  The steam
  322.           is still produced, it just isn't allowed to turn turbines and 
  323.           generate power.  Once a TURBINE TRIP is initiated it can not be 
  324.           stopped, and a significant core overhaul will be needed.  Be
  325.           certain you need to use this command before entering it.  It should
  326.           only be used in case of extreme emergency.
  327.  
  328.    V = Value command.
  329.  
  330.    VALUE = Displays the current value of the power generated by the plant.
  331.           The starting price is $21.49 per mega-watts per hour.  The value
  332.           is increased by refueling and pretesting the reactor prior to 
  333.           power up.
  334.  
  335.    VALVE 1 OPEN = Opens the by-pass valves for steam flowing through Turbine
  336.           Group #1.  When this valve is open a 50% drop in power output is
  337.           is seen and once open, it will remain that way until the valve is
  338.           closed with a VALVE 1 CLOSED command.  If both VALVE #1 and #2 are
  339.           open, no power is generated since all steam is by-passed from the
  340.           turbines.  This has the same effect as a Turbine Trip but unlike
  341.           the turbine trip it can be aborted by closing the valves
  342.  
  343.    VALVE 1 CLOSED = Closes the by-pass valves for Turbine Group #1.
  344.  
  345.    VALVE 2 OPEN = Opens the by-pass valves for steam flowing through Turbine
  346.           Group #2.  When this valve is open a 50% drop in power output is
  347.           seen, and once open it will remain that way until the valve is
  348.           closed with a VALVE 2 CLOSED command.  If both VALVES #1 and #2 are
  349.           open, no power is generated since all steam is being by-passed from
  350.           the turbines.  This has the same effect as a Turbine Trip but unlike
  351.           the turbine trip it can be aborted by closing the valves
  352.  
  353.    VALVE 2 CLOSED = Closes the by-pass valves for Turbine Group #2.
  354.  
  355.    VIEW ON = Activates the automatic changing of the view screen.  Every
  356.           15 seconds the view screen will change to the next <F9> screen.
  357.           If any screen is changed manually using the <F6> or <F9> keys it
  358.           will reset the 15 second timer to 0.
  359.  
  360.    VIEW OFF = De-activates automatically changing view screen.
  361.           
  362.  
  363.  
  364.  
  365.                      --<<< SIMULATOR HOT KEY LIST >>>--
  366.  
  367.       <F1> = Display the Command Summary/Help File (OAKFLAT.HLP)
  368.  
  369.       <F2> = Enter Control Rod Setting.
  370.  
  371.       <F3> = Enter Primary Coolant Pump Rate.
  372.  
  373.       <F4> = Enter Secondary Coolant Pump Rate.
  374.  
  375.       <F5> = Enter Reserve Coolant Pump Rate.
  376.  
  377.       <F6> = Display Main Control Panel.
  378.  
  379.       <F7> = Enter Simulator Command.
  380.  
  381.       <F8> = Damage Control.
  382.  
  383.       <F9> = Display/Change Simulator Status Reports.
  384.  
  385.       <F10> = More Function Key Help While On-Line.
  386.  
  387.       <KEYPAD CURSOR KEYS> = Change Forward/Backward Simulator Status Reports.
  388.  
  389.